6 citations
,
July 2005 in “Farmaco” This study developed a micellar electrokinetic capillary chromatography method for determining minoxidil in Rogaine and generic products, offering a simple and efficient alternative to HPLC.
January 2018 in “Journal of analytical, bioanalytical and separation techniques”
1 citations
,
March 2015 in “Oriental Journal of Chemistry/Oriental journal of chemistry” This study developed and validated a precise RP-HPLC method for simultaneously estimating minoxidil and aminexil in pharmaceutical formulations with good accuracy and specificity.
January 2025 in “International Journal of Drug Delivery Technology” In this study, researchers developed a reliable HPLC method to simultaneously estimate Finasteride and Tadalafil in marketed formulations, showing precise, linear results with confirmed degradation susceptibility under certain stress conditions.
January 2015 in “DOAJ (DOAJ: Directory of Open Access Journals)” This study developed a precise and simple HPLC method for estimating tamsulosin and finasteride simultaneously in pharmaceutical forms, demonstrating good precision and potential usefulness for combined dosage analysis.
This study established an HPLC-MS method for measuring oxymatrine in human plasma and used it to examine the pharmacokinetics of its capsules.
5 citations
,
January 2011 in “Der Pharmacia Lettre” This study validated a precise and sensitive reverse phase high performance liquid chromatographic method for determining Finasteride and Tamsulosin concentrations in bulk and tablet forms, with satisfactory accuracy and reproducibility.
December 2023 in “International Journal of Advanced Research in Science, Communication and Technology” This study developed and validated a precise and rapid HPLC method to simultaneously determine Minoxidil and Finasteride in pharmaceuticals, demonstrating successful application for routine quality control without interference from excipients.
January 2015 in “INDONESIAN JOURNAL OF PHARMACY” This study developed a simple HPLC method for accurately estimating tamsulosin and finasteride in pharmaceutical forms, demonstrating good precision and potential application in combined dosage analysis.
1 citations
,
January 2005 in “Chinese Journal of Hospital Pharmacy” This study developed a stable and reliable HPLC-ESI-MS method for determining finasteride levels in human plasma, suitable for pharmacokinetic studies.
1 citations
,
September 2016 in “Acta Chromatographica” This study validated a new RP-HPLC method for accurately determining doxazosin mesylate and finasteride in bulk powders and capsule formulations.
4 citations
,
January 2011 in “Analytical Letters” This study demonstrated that a flow injection method using potassium permanganate for detecting minoxidil provided accurate recoveries and agreed closely with HPLC results, showing potential for effective analysis of commercial samples.
January 2010 in “World Clinical Drugs” This study successfully applied an optimized LC-MS/MS method for accurately determining finasteride concentrations and assessing its pharmacokinetics in healthy volunteers.
June 2025 in “Indian Journal of Heterocyclic Chemistry” In this study, researchers developed a precise and rapid method for simultaneously analyzing minoxidil and finasteride in local therapeutic formulations, ensuring that the excipients did not interfere, making it suitable for routine quality control.
1 citations
,
October 2020 in “Annales pharmaceutiques françaises” In this study, researchers developed and validated a rapid and robust chromatographic method to assess the concentration of Minoxidil and Finasteride in a new topical formulation for alopecia, demonstrating its ability to distinguish between different types of formulations using in vitro diffusion data.
This study established a simple, accurate, and precise HPLC method for determining the content and content uniformity of finasteride capsules.
25 citations
,
October 2008 in “Chromatographia” This study developed and validated a sensitive and rapid method to simultaneously measure alfuzosin and dutasteride in human plasma, enabling high-throughput analysis for pharmacokinetic and bioequivalence studies.
September 2024 in “International Journal of Applied Pharmaceutics” This study describes a new LC-MS/MS method for analyzing Finasteride and Tadalafil, demonstrating system suitability, linearity, and accuracy in pharmacokinetic studies in rats, aligning with USFDA guidelines.
3 citations
,
July 2022 in “BMC chemistry” This study introduced and validated new spectrophotometric methods to simultaneously determine finasteride and tadalafil in Entadfi™ capsules with high sensitivity and without interference from excipients.
January 2007 in “Zhōnghuá yàoxué zázhì” This study concluded that two exemestane preparations are bioequivalent, using a high-performance liquid chromatographic mass spectrometric method to measure concentrations in human plasma.
8 citations
,
October 2015 in “Asian Journal of Chemistry” A new method was created to accurately measure minoxidil and aminexil in hair loss treatments.
5 citations
,
February 2014 in “Journal of Liquid Chromatography & Related Technologies” This study successfully developed and validated a reverse-phase HPLC method for accurately determining finasteride and tamsulosin simultaneously in bulk and pharmaceutical formulations.
1 citations
,
January 2012 in “Analytical chemistry, an Indian journal” This study successfully developed and validated a sensitive and precise liquid chromatography method for simultaneously estimating tamsulosine hydrochloride and finasteride in tablets, showing high accuracy and minimal interference from excipients.
January 2004 in “Zhongguo yaoke daxue xuebao” This study found that two finasteride preparations were bioequivalent in human volunteers when tested using a new HPLC method for pharmacokinetics.
This investigation reports a new RP-HPLC method for accurately estimating Finasteride and Tamsulosin Hydrochloride in bulk and tablet forms, which may serve in routine pharmaceutical analysis.
5 citations
,
February 2013 in “Journal of Liquid Chromatography & Related Technologies” This study developed and validated a micellar electrokinetic chromatography method to determine finasteride stability, finding that the drug degrades under acidic, basic, and oxidative stress conditions.
12 citations
,
August 2016 in “Biomedical Chromatography” This study developed and validated an HPLC-UV method for accurately quantifying clobetasol propionate in skin and hair follicles, demonstrating its application in in vitro permeation experiments.
5 citations
,
January 2012 in “PubMed” This study developed and validated a reliable method using chromatography and mass spectrometry to accurately measure finasteride levels in human plasma.
December 2022 in “Journal of Natural Remedies” This study found that compounds extracted from Cucurbita maxima seeds at 50 °C for 2 hours demonstrated significant binding affinities against breast cancer-related proteins, suggesting potential anticancer activity needing further in vitro and in vivo evaluation.
10 citations
,
June 2013 in “Talanta” This study demonstrated a validated UPLC method for analyzing finasteride in low-dose drug products, highlighting methanol content and flow rate as critical factors for method robustness and accuracy.