2 citations
,
May 2006 in “Journal of Separation Science” This study describes a capillary GC method for accurately measuring spermidine levels in hair lotions, confirming its precision and specificity for this application.
2 citations
,
September 2018 in “Journal of Separation Science” This study demonstrated that using finasteride impurity as a non-isotopically labeled internal standard in paper spray ionization–mass spectrometry can effectively and efficiently measure finasteride tablet dissolution, achieving results comparable to high-performance liquid chromatography.
1 citations
,
June 2020 in “Journal of AOAC INTERNATIONAL” This study reports that two novel chromatographic methods demonstrated high sensitivity and selectivity for determining aminexil, niacinamide, and pyridoxine HCl in a laboratory-prepared mixture and hair tonic preparation.
2 citations
,
October 2010 in “European Journal of Drug Metabolism and Pharmacokinetics” Researchers developed a quick and sensitive way to measure finasteride in blood using a small sample size.
15 citations
,
November 2006 in “Journal of Pharmaceutical and Biomedical Analysis” This study developed and validated a reliable method to measure finasteride levels in human plasma, which was successfully used to assess its pharmacokinetics after a 5 mg dose in healthy volunteers.
19 citations
,
May 1991 in “Journal of Chromatography B: Biomedical Sciences and Applications” This study developed and validated an HPLC method for detecting a novel 5α-reductase inhibitor in human plasma, supporting its pharmacokinetic evaluation at low doses.
11 citations
,
January 2006 in “Analytica Chimica Acta” Validated method reliably measures finasteride in tablets using liquid chromatography.
January 2019 in “Arabian Journal of Chemistry” This study developed and validated an HPLC method to quantify impurities in finasteride, demonstrating its suitability for quality assurance of the drug and its related substances.
April 2016 in “Annals of laboratory medicine” The researchers reported that epitestosterone treatment reduced eicosanoid levels generated by cyclooxygenases and lipoxygenases in rabbit liver samples with carrageenan-induced inflammation.
51 citations
,
February 2010 in “Analytical and Bioanalytical Chemistry” Researchers developed a method to detect hormone-blocking drugs in wastewater and found them in Beijing's sewage, suggesting they can survive sewage treatment.
11 citations
,
September 2020 in “Steroids” This study developed a new method using liquid chromatography-tandem mass spectrometry to measure multiple steroid hormones in hair, requiring significantly fewer strands than previous methods, with high accuracy and precision.
5 citations
,
February 2013 in “Journal of Liquid Chromatography & Related Technologies” This study developed and validated a micellar electrokinetic chromatography method to determine finasteride stability, finding that the drug degrades under acidic, basic, and oxidative stress conditions.
1 citations
,
January 2017 in “Asian Journal of Chemistry” New method effectively analyzes finasteride and its stability.
January 2026 in “National Journal of Pharmaceutical Sciences” This study developed and validated a Gas Chromatography-Flame Ionization Detection method for assessing minoxidil, which shows good precision, accuracy, and specificity for quality control and pharmacokinetic studies.
17 citations
,
August 2015 in “Journal of steroid biochemistry and molecular biology/The Journal of steroid biochemistry and molecular biology” This study concluded that the best approach for detecting Androsta-1,4,6-triene-3,17-dione administration in horses is monitoring the metabolites M1b or M4 in urine, detectable up to 77 hours post-administration.
45 citations
,
June 2008 in “Journal of pharmaceutical and biomedical analysis” This study developed a new HPLC method for detecting prohibited substances like minoxidil and hydrocortisone in cosmetic products, achieving high sensitivity and successful application to real-world samples.
45 citations
,
August 1994 in “Journal of Chromatography B: Biomedical Sciences and Applications” Method detects finasteride in plasma and semen with high sensitivity and accuracy.
29 citations
,
February 1996 in “Journal of Chromatography B: Biomedical Sciences and Applications” This study developed a fully automated HPLC method for accurately quantifying finasteride in human plasma, achieving a detection limit of 1 ng/ml with validated application in pharmacokinetic studies.
13 citations
,
November 2006 in “E-journal of Chemistry” This study developed a rapid and sensitive HPLC method for measuring finasteride in bulk and tablet forms, showing high precision and accuracy compared to the official method.
11 citations
,
August 2017 in “Journal of Chromatographic Science” This study established a rapid and accurate ultra-performance liquid chromatographic method for chemical fingerprinting and analyzing Platycladi cacumen, effectively distinguishing batches based on geographical and climatic conditions.
10 citations
,
January 2019 in “Journal of Chromatography B” This study used a newly validated method to find that one-year finasteride treatment resulted in no significant differences in urinary androgen and prostaglandin levels between male pattern baldness patients and normal controls.
1 citations
,
November 2025 in “Clinical Chemistry and Laboratory Medicine (CCLM)” This study developed a new measurement procedure using isotope dilution-liquid chromatography-tandem mass spectrometry for accurate quantification of DHEAS in human serum or plasma, demonstrating high selectivity, sensitivity, and low measurement uncertainty, making it suitable for routine standardization and clinical evaluation.
January 2026 in “Clinical Chemistry and Laboratory Medicine (CCLM)” This study reported high analytical performance of an RMP for DHT quantification, with the ability to differentiate between 5α-DHT and 5β-DHT isomers, making it suitable for routine assay standardization and clinical sample evaluation.
August 2025 in “İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi” In this study, the researchers developed a chromatographic method to determine α-tocopherol and α-tocopheryl acetate in pharmaceutical capsules with high accuracy and repeatability, establishing it as a reliable alternative for analyzing these compounds.
71 citations
,
January 2014 in “Journal of Proteome Research” In this study, distinct metabolic profiles were identified in women with PCOS, suggesting potential biomarkers for diagnosis based on changes in lipid and androgen metabolism.
18 citations
,
July 2009 in “Drug Metabolism and Disposition” This study identified previously unknown phase I and phase II metabolites of finasteride in human bile and urine using a specialized bile collection technique and advanced mass spectrometry analysis.
9 citations
,
February 2018 in “Journal of Pharmaceutical and Biomedical Analysis” This study validated a highly selective and fast LC–MS/MS method for accurately measuring levels of tadalafil and finasteride in human plasma, adhering to international bioanalytical guidelines.
1 citations
,
April 2015 in “Drug research” This study concluded that two different pharmaceutical formulations of finasteride were bioequivalent in terms of rate and extent of absorption based on pharmacokinetic evaluations in a randomized crossover study with 38 volunteers.
1 citations
,
March 1997 in “Journal of Chromatography B: Biomedical Sciences and Applications” This study discovered that the disposition of LY191704 enantiomers in rats and dogs is both stereoselective and species specific.
32 citations
,
November 2004 in “Journal of pharmaceutical sciences” This study quantifies the follicular uptake of tea tree oil in bovine udder skin, with microemulsion showing the highest concentration among different formulations tested.