Stability Indicating Method Development and Validation of Finasteride by High-Performance Thin-Layer Chromatography Studies

    January 2017 in “ Asian Journal of Chemistry
    Sanjay D. Sawant, Minal R. Ghante
    New to Finasteride? There is a guide in the encyclopedia. Read the guide →
    Image
    Studysummary New method effectively analyzes finasteride and its stability.
    Our plain-language summary. Not medical advice or a treatment recommendation. Consult a qualified healthcare professional before changing treatment. Full disclaimer
    This document describes the development and validation of a stability-indicating method for analyzing finasteride using high-performance thin-layer chromatography (HPTLC). The method involves preparing a standard stock solution of finasteride, selecting a mobile phase of chloroform:methanol, and running the TLC plate for 70 mm. The calibration curve, precision, robustness, limit of detection and quantitation, specificity, recovery studies, and analysis of finasteride in a tablet formulation are also discussed. Forced degradation studies of finasteride were conducted under various stress conditions, and the results are presented in a table. Overall, the method was found to be suitable for analyzing finasteride and determining its stability under different conditions.
    Discuss this study in the Community →