100 citations
,
October 2006 in “Rapid Communications in Mass Spectrometry” This study describes a fast LC/MS/MS method for detecting various synthetic drugs in urine, meeting World Anti-Doping Agency performance limits.
10 citations
,
July 2001 in “Hair transplant forum international” This article discusses challenges in hair restoration surgery and reports no new clinical results.
39 citations
,
January 2015 in “Journal of Electroanalytical Chemistry” In this study, a novel electrochemical sensor using a molecularly imprinted polymer was developed for the sensitive detection of minoxidil, successfully measuring its concentration in real samples.
January 1990 in “Medical Entomology and Zoology” This study developed a faster method for analyzing fatty acid ethyl esters in hair to help detect alcohol consumption levels, showing potential for applications in forensic and clinical settings.
36 citations
,
July 2004 in “Journal of Controlled Release” This study demonstrates that confocal laser scanning microscopy can effectively visualize the rapid diffusion and penetration pathway of a dye into the hair follicle in fresh human scalp skin.
September 2024 in “Skin Research and Technology” This study used atomic force microscopy to identify significant morphological differences in hair from patients with lichen planopilaris compared to healthy controls, noting more scratches, uneven edges, and pitted scales in affected hair, which may aid future research on the condition.
February 2009 in “Journal of The American Academy of Dermatology” This pilot study found that fractional infrared technology improved skin laxity and thickness in the cervical area of four female patients without causing adverse effects.
12 citations
,
November 2019 in “South African Medical Journal” This study found that the pH levels of relaxers tested were corrosive to the skin and may contribute to alopecia in females with afro-textured hair.
40 citations
,
January 2010 in “International Journal of Trichology” This review discusses the diagnostic criteria and guidelines for managing loose anagen syndrome and differentiating it from non-scarring alopecias, but it reports no new clinical results.
18 citations
,
December 2010 in “Journal of analytical atomic spectrometry” This study demonstrated that using lead-doped keratin film as a calibration standard allows for accurate tracking of lead distribution along hair strands, revealing different exposure patterns among workers in a battery manufacturing factory in Thailand.
66 citations
,
August 2007 in “Applied and environmental microbiology” This study engineered a bioluminescent yeast strain responsive to androgenic chemicals, demonstrating rapid and sensitive detection suitable for high-throughput screening and environmental monitoring.
22 citations
,
July 2010 in “Drug Testing and Analysis” This study presents a rapid method for detecting multiple xenobiotics in urine, effectively identifying 45 compounds banned in sports with detection limits below WADA's performance levels.
3 citations
,
July 2016 in “Tropical Journal of Pharmaceutical Research” This study found that the proposed LC-MS/MS method accurately quantified the drug content in split tablets of finasteride and terbinafine, revealing significant variability and suggesting that non-scored tablets should not be split.
44 citations
,
October 2020 in “Arthritis Care & Research” This review summarizes various indices used to assess disease activity and damage in systemic lupus erythematosus, highlighting challenges in universal consensus and their practical applications in research and clinical settings.
7 citations
,
November 2022 in “Toxics” This study developed and validated a highly sensitive LC-MS/MS method for detecting multiple steroid hormones in urine and serum/plasma, demonstrating its potential for use in large-scale biomonitoring studies.
8 citations
,
October 2014 in “Journal of analytical toxicology.” This study found that a single application of 'Lye' or 'No-Lye' chemical straighteners significantly reduced drug concentrations in hair samples from both drug-fortified standards and authentic drug users.
19 citations
,
September 1999 in “Talanta” New method measures minoxidil concentration faster, more accurately, and automatically.
May 2019 in “Clinica chimica acta” This study reported that mice with more diverse gut microbiota showed higher hair levels of certain hormones and 1-AG compared to those with less diverse microbiota, though plasma differences were more complex and varied by stress and sex.
August 2018 in “Journal of Investigative Dermatology” This study found that combining optical clearing methods with light-sheet fluorescence microscopy allows detailed 3D visualization of normal and pathological human skin biopsies, revealing differences in epidermal thickness and volume.
30 citations
,
July 2023 in “Clinical Chemistry and Laboratory Medicine (CCLM)” In this study, researchers developed an LC-MS/MS method to accurately quantify cortisone and cortisol levels in human scalp hair, finding that concentrations decrease predictably along the hair shaft, which could assist in identifying abnormal glucocorticoid exposure.
4 citations
,
January 1993 in “Clinical Chemistry and Laboratory Medicine (CCLM)” This study developed a highly sensitive fluorescent assay for measuring enzyme activity in single hair follicles, allowing the efficient analysis of over 100 samples per day.
9 citations
,
November 2022 in “International Journal of Molecular Sciences” This study found that LC-MS/MS assays provided more reliable and precise steroid measurements in human serum compared to traditional immunoassays, particularly at lower concentrations.
March 2022 in “VNU Journal of Science Medical and Pharmaceutical Sciences” This study developed a sensitive method using LC-ESI-MS/MS for accurate and reliable measurement of nine steroid hormones in children's serum.
January 2023 in “Brazilian Journal of Pharmaceutical Sciences” This study concluded that the liquid chromatography-mass spectrometry method developed is viable for accurately quantifying spironolactone and its metabolite canrenone in plasma despite interference from plasma components.
March 2026 in “Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials” This study investigated the mechanical response of the human hair cuticle to strain and found that cuticular deformation directly corresponded with fiber elongation, revealing significant molecular-level changes in disulfide crosslinks but maintained structural stability, highlighting the role of the cuticle in stress resistance.
96 citations
,
September 2017 in “Analytica Chimica Acta” This review discusses the growing use of scalp hair for elemental analysis in various fields and highlights advancements in analysis techniques, including the future potential of laser ablation ICP-MS, but reports no new clinical results.
21 citations
,
November 2010 in “Talanta” This study reported the development of a novel and reliable liquid chromatographic method to measure testosterone and epitestosterone in human urine, offering sensitive detection for doping control.
2 citations
,
December 2019 in “Bioanalysis” This article reviews analysis techniques in LC-MS/MS and discusses the potential use of a novel in-sample calibration curve method, but reports no new experimental results.
9 citations
,
May 2020 in “Journal of Pharmaceutical and Biomedical Analysis” This study developed an efficient LC-MS bioanalytical method to simultaneously quantify minoxidil sulphate and latanoprost in skin layers, supporting the formulation of topical treatments for androgenic alopecia.
March 2026 in “Mendeley Data” In this study, researchers developed an open-source browser-based tool to enhance the reproducibility and accuracy of SALT score calculations from scalp photos, aimed particularly at assessing partial regrowth in alopecia areata patients on JAK inhibitor therapy.