January 2005 in “Yaowu fenxi zazhi” This study established a convenient, accurate, and sensitive HPLC-APCI-MS method for determining finasteride in human plasma, suitable for pharmacokinetic studies.
January 2005 in “Yaowu fenxi zazhi” This study established a mathematical model for measuring uncertainty in the HPLC determination of tablet content and content uniformity, which the authors concluded to be reasonable and reliable.
January 2005 in “Yaowu fenxi zazhi” This study concluded that domestic and imported finasteride tablets are bioequivalent, with no significant differences in their pharmacokinetics among healthy volunteers.
January 2004 in “Zhongguo yaoke daxue xuebao” This study found that two finasteride preparations were bioequivalent in human volunteers when tested using a new HPLC method for pharmacokinetics.
January 2003 in “Pharmaceutical Journal of Chinese People's Liberation Army” This study developed a simple and accurate HPLC method to determine the dissolution of finasteride tablets, achieving a high recovery rate and linear calibration for finasteride detection.
This study established a simple, accurate, and precise HPLC method for determining the content and content uniformity of finasteride capsules.
21 citations
,
March 2021 in “Molecules” This study found that a new quercetin-loaded self-nanoemulsifying drug delivery system improved quercetin bioavailability by 149.8% compared to its suspension in rats.
8 citations
,
October 2015 in “Asian Journal of Chemistry” A new method was created to accurately measure minoxidil and aminexil in hair loss treatments.
5 citations
,
January 2011 in “Der Pharmacia Lettre” This study validated a precise and sensitive reverse phase high performance liquid chromatographic method for determining Finasteride and Tamsulosin concentrations in bulk and tablet forms, with satisfactory accuracy and reproducibility.
4 citations
,
December 2018 in “Macedonian Journal of Chemistry and Chemical Engineering” This study developed a reliable RP-HPLC-DAD method, finding that amino acid concentrations in bleached hair decrease with higher hydrogen peroxide levels, notably affecting cystine.
3 citations
,
May 2014 in “PubMed” This study used a newly developed RP-HPLC method to accurately measure finasteride distribution in human cadaver skin after applying different vesicular drug delivery systems.
3 citations
,
January 2012 This study developed and validated an RP-HPLC-PDA method for accurately estimating Tamsulosin and Finasteride in bulk and tablet forms, achieving precise detection and linearity within specified concentration ranges.
1 citations
,
October 2020 in “Annales pharmaceutiques françaises” In this study, researchers developed and validated a rapid and robust chromatographic method to assess the concentration of Minoxidil and Finasteride in a new topical formulation for alopecia, demonstrating its ability to distinguish between different types of formulations using in vitro diffusion data.
1 citations
,
March 2015 in “Oriental Journal of Chemistry/Oriental journal of chemistry” This study developed and validated a precise RP-HPLC method for simultaneously estimating minoxidil and aminexil in pharmaceutical formulations with good accuracy and specificity.
1 citations
,
January 2012 in “Analytical chemistry, an Indian journal” This study successfully developed and validated a sensitive and precise liquid chromatography method for simultaneously estimating tamsulosine hydrochloride and finasteride in tablets, showing high accuracy and minimal interference from excipients.
1 citations
,
December 2009 in “Asian Journal of Research in Chemistry” This study developed and validated ultraviolet spectrophotometric and reversed phase high performance liquid chromatographic methods for simultaneously estimating Tamsulosin and Finasteride in tablet form, showing statistical validation and effectiveness in pharmaceutical analysis.
January 2025 in “International Journal of Drug Delivery Technology” In this study, researchers developed a reliable HPLC method to simultaneously estimate Finasteride and Tadalafil in marketed formulations, showing precise, linear results with confirmed degradation susceptibility under certain stress conditions.
June 2024 in “International Journal of Pharmaceutical Quality Assurance” This study established a new reverse-phase high-performance liquid chromatography method to accurately and precisely quantify silodosin and dutasteride in mixtures, meeting International Council of Harmonization validation criteria for stability, sensitivity, and recovery.
January 2024 in “International Journal of Biological and Environmental Investigations” This study developed and validated a reliable RP-HPLC method for accurately quantifying dutasteride in pharmaceutical formulations and bulk pharmaceuticals using a Shiseido C18 analytical column, demonstrating precision, accuracy, and sensitivity across a concentration range of 10 to 22 ppm.
January 2023 in “Zenodo (CERN European Organization for Nuclear Research)” This study developed a reliable RP-HPLC method for the simultaneous estimation of Spironolactone and Hydrochlorothiazide, which was validated as accurate, precise, and robust for pharmaceutical applications.
This investigation reports a new RP-HPLC method for accurately estimating Finasteride and Tamsulosin Hydrochloride in bulk and tablet forms, which may serve in routine pharmaceutical analysis.
This study developed and validated three analytical techniques for the simultaneous quantification of Finasteride and Tamsulosin Hydrochloride in pharmaceutical dosage forms, with proven accuracy and precision.
February 2021 in “European Chemical Bulletin” This study developed and validated a reverse phase liquid chromatography method to accurately and reliably measure Minoxidil and Finasteride in bulk and marketed formulations.
May 2019 in “Asian Journal of Chemistry” Finasteride forms three new products under acidic stress.
January 2015 in “INDONESIAN JOURNAL OF PHARMACY” This study developed a simple HPLC method for accurately estimating tamsulosin and finasteride in pharmaceutical forms, demonstrating good precision and potential application in combined dosage analysis.
January 2015 in “DOAJ (DOAJ: Directory of Open Access Journals)” This study developed a precise and simple HPLC method for estimating tamsulosin and finasteride simultaneously in pharmaceutical forms, demonstrating good precision and potential usefulness for combined dosage analysis.
26 citations
,
June 2010 in “Acta Pharmaceutica” The researchers reported that they successfully developed and validated RP-HPLC and TLC methods for accurately measuring tamsulosin hydrochloride and finasteride in combination forms.
20 citations
,
October 2004 in “Journal of Pharmaceutical and Biomedical Analysis” Quick method to measure minoxidil in blood, accurate and useful for labs.
January 2020 in “International Journal of Research in Pharmacy and Chemistry” This study developed a validated HPLC method for accurately estimating dutasteride and its related compounds in capsules, suitable for routine and stability sample analysis.
4 citations
,
December 2020 in “Natural Product Sciences” This study identified ten compounds from Eclipta prostrata, with some displaying potent inhibitory effects against α-glucosidase and acetylcholinesterase enzymes.